- Reduce the starting current, reduce power supply peak current, reduce the cost of distribution equipment. Reduce the abrasion of motor, improve the service life of mechanical equipment.
- Optional starting parameters are convenient in one soft starter starting different motors.
- Soft starter inspects motor feedback voltage to realize closed loop control, ensure the motor start-up success in different conditions and different loads.
- A variety of starting ways: voltage ramp starting way can get the maximum output torque; Current limiting can realize biggest limitations of the soft start starting current.
- Reliable quality assurance: using computer simulation design; SMT production process; Excellent electromagnetic compatibility performance; High temperature aging, vibration test of the machine before delivery.
- Perfect and reliable protection function: loss of voltage, less voltage, over voltage protection; overheating, starting time too long; Input phase lost, output phase lost, three-phase imbalance; starting over current, overload and load short circuit protection, etc.
- Full dynamic control field-bus monitoring starter, easy networking.
- LED displaying screen can display parameter code, state and error.
Mô hình |
Quyền lực |
Hiện hành |
Bên ngoài
D imensions (mm) |
Kích thước lắp đặt (mm) |
NW |
220V |
380V |
480V |
(KW) |
(A) |
H 1 |
W 1 |
D |
H2 |
W2 |
D |
(KILOGAM) |
--- |
EM-GJ3-5d5 |
EM-GJ4-5d5 |
5,5 |
11 |
270 |
146 |
160 |
248 |
132 |
M7 |
5 |
--- |
EM-GJ3-7d5 |
EM-GJ4-7d5 |
7,5 |
15 |
270 |
146 |
160 |
248 |
132 |
M7 |
5 |
EM-GJ2-5d5 |
EM-GJ3-011 |
EM-GJ4-011 |
5,5 / 11 |
23 |
270 |
146 |
160 |
248 |
132 |
M7 |
5 |
EM-GJ2-7d5 |
EM-GJ3-015 |
EM-GJ4-015 |
7,5 / 15 |
30 |
270 |
146 |
160 |
248 |
132 |
M7 |
5 |
--- |
EM-GJ3-018 |
EM-GJ4-018 |
18,5 |
37 |
270 |
146 |
160 |
248 |
132 |
M7 |
5 |
EM-GJ2-011 |
EM-GJ3-022 |
EM-GJ4-022 |
11/22 |
43 |
270 |
146 |
160 |
248 |
132 |
M7 |
5 |
EM-GJ2-015 |
EM-GJ3-030 |
EM-GJ4-030 |
15/30 |
60 |
270 |
146 |
160 |
248 |
132 |
M7 |
5 |
EM-GJ2-018 |
EM-GJ3-037 |
EM-GJ4-037 |
18,5 / 37 |
75 |
270 |
146 |
160 |
248 |
132 |
M7 |
5 |
EM-GJ2-022 |
EM-GJ3-045 |
EM-GJ4-045 |
22/45 |
90 |
270 |
146 |
160 |
248 |
132 |
M7 |
5 |
EM-GJ2-030 |
EM-GJ3-055 |
EM-GJ4-055 |
30/55 |
110 |
270 |
146 |
160 |
248 |
132 |
M7 |
5 |
EM-GJ2-037 |
EM-GJ3-075 |
EM-GJ4-075 |
37/75 |
150 |
270 |
146 |
160 |
248 |
132 |
M7 |
5 |
EM-GJ2-045 |
EM-GJ3-090 |
EM-GJ4-090 |
45/90 |
180 |
525 |
257 |
198 |
382 |
192 |
M9 |
21 |
EM-GJ2-055 |
EM-GJ3-115 |
EM-GJ4-115 |
55/115 |
230 |
525 |
257 |
198 |
382 |
192 |
M9 |
21 |
--- |
EM-GJ3-132 |
EM-GJ4-132 |
132 |
264 |
525 |
257 |
198 |
382 |
192 |
M9 |
21 |
EM-GJ2-075 |
EM-GJ3-160 |
EM-GJ4-160 |
75/160 |
320 |
525 |
257 |
198 |
382 |
192 |
M9 |
21 |
EM-GJ2-090 |
EM-GJ3-185 |
EM-GJ4-185 |
90/185 |
370 |
525 |
257 |
198 |
382 |
192 |
M9 |
21 |
EM-GJ2-100 |
EM-GJ3-200 |
EM-GJ4-200 |
100/200 |
400 |
525 |
257 |
198 |
382 |
192 |
M9 |
21 |
EM-GJ2-132 |
EM-GJ3-250 |
EM-GJ4-250 |
132/250 |
500 |
525 |
257 |
198 |
382 |
192 |
M9 |
21 |
EM-GJ2-160 |
EM-GJ3-280 |
EM-GJ4-280 |
160/280 |
560 |
525 |
257 |
198 |
382 |
192 |
M9 |
21 |
EM-GJ2-185 |
EM-GJ3-320 |
EM-GJ4-320 |
185/320 |
640 |
570 |
290 |
248 |
460 |
260 |
M9 |
25 |
--- |
EM-GJ3-355 |
EM-GJ4-355 |
355 |
640 |
570 |
290 |
248 |
460 |
260 |
M9 |
25 |
EM-GJ2-200 |
EM-GJ3-400 |
EM-GJ4-400 |
200/400 |
800 |
590 |
330 |
248 |
497 |
265 |
M9 |
30 |
EM-GJ2-220 |
EM-GJ3-450 |
EM-GJ4-450 |
220/450 |
900 |
590 |
330 |
248 |
497 |
265 |
M9 |
30 |
EM-GJ2-250 |
EM-GJ3-500 |
EM-GJ4-500 |
250/500 |
1000 |
665 |
410 |
248 |
547 |
350 |
M9 |
42 |
EM-GJ2-315 |
EM-GJ3-600 |
EM-GJ4-600 |
315/600 |
1200 |
665 |
410 |
248 |
547 |
350 |
M9 |
42 |
General purpose soft start motor control applications where traditional across-the-line starting or wye-delta starting would typically be appropriate. Typical application types include:
-
Motor fan:use soft starter instead of conventional starter, to realize the smooth start.
-
Compressor: The soft starter limit the startup current, reduce the abrasion and mechanical impact, reduce the heat of motor, prolong the working life, save the maintenance cost.
-
Crusher: The block protection of soft starter prevent the motor being over burnt and hurt damaged come from mechanical fault and block.
-
Transmission machine: soft startup and presetting slow movement realize smooth, gradual start, to avoid products movement and liquid overflow.
-
Pump: the control of soft starter reduce the water hammer result from liquid impact, saving maintenance cost for system.
-
Grinder: The soft start reduce the abrasion of wheels, lighten the maintenance cost and tiem.
- Agitator
- Air Compressor
- Ball Mill
- Centrifuge
- Chiller
- Conveyor
- Crusher
- Escalator
- Fan (Low and High Inertia)
- Feeder
- Grinder
- Hammer Mill
- Lathe Machine
- Mills (Flour, etc.)
|
- Mixer (Unloaded or Loaded)
- Pelletizer
- Plastic and Textile Machines
- Press (Flywheel)
- Pump (Centrifugal)
- Pump (Positive Displacement)
- Rolling Mill
- Saw (Band)
- Saw (Circular)
- Screen (Vibrating)
- Transformer
- Tumbler
- Wood Chipper
|